Fireplace from Hell
I was approached to do a fireplace with a unique non-functioning section on the side for firewood to be stacked. They wanted a dark color and a smooth style. So I completed what would be (much to my chagrin) my first of 3 attempts.
Everything went well, the customer loved the look. I darkened with some glaze and then waxed for the finish. The contractor did not tell me that it was supposed to be a floor to ceiling look so I had quite a bit of work to do.
Note on floor to ceiling looks: Regardless of how good the builder or designer is, this is a detail that is constantly overlooked. It is NOT an easy fix. Because of this I have included it in the planning at every meeting to make sure the prep is done correctly ahead of time.
Then the cracking started. It was minimal, and very unexpected as I applied the finish like I always do. So I came back, cut out the drywall lines, put new tape in, and floated out the style once more.
Looked great, and the homeowner was happy.
Then it happened again. This struck me as very odd as this had never occurred previously and I had done everything to spec.
But, I won’t leave the customer hanging, so I came back again. I redid all tape lines and floated everything on the face back out once more. The fireplace looked great and the customers were happy.
Then a month later, it began cracking again.
This was quite perturbing, so I dove into the build with the customers (the contractors on site, come to fine out, had no idea what they were doing).
I was originally told that the fireplace was electric—It was not. This is a completely different system for this that I would have applied but was not made aware of.
So I recommended some contractors I trusted to the homeowner and they tore the whole face off to replace with durarock.
You see, the problem with wood studs and drywall is that it does nothing to stop the two biggest issues with gas fireplaces, heat and torsion.
So the rock was shimmed, I applied corners, and a Schluter Kerdi stystem. This involved a coupling barrier and 4 layers of mortar to get smooth.
After that I was able to apply adhesive primer and applied Microcement instead of traditional Venetian to the face. The added polymers give increased strength.
This system was able to handle the significant increase in heat which can cause expansion/contraction.
The fireplace has held up brilliantly since then. The customer was not charged, as I stand behind all work and the warranty behind it.
The learning has been done, so ever since then I am extremely particular with fireplace specs, tolerances, units, inserts, and prep work. When you are dedicated to the craft you learn and move on to the next project!
Client review Dr. Rubin:
“We had the pleasure of working with Taylor to finish our fireplace in a complete remodel. He is truly an artist and very skilled. He was always very prompt, friendly, and professional. His accountability was not lacking. We hired him for Venetian plaster and microcement and both were beautiful. The Venetian was sultry and the microcement stunning. He was able to portray movement and fluidity without being gaudy and provided smooth texture. He was able to trouble shoot some cracking and deliver an amazing look for our home. HIGHLY recommend Taylor.”